Vulnerable Application

Unitronics Vision PLCs using PCOM protocol

Verification Steps

  1. Do: use scanner/scada/pcomclient

  2. Do: set RHOST=IP where IP is the IP address of the target

  3. Do: run to send PCOM command

Scenarios

msf > use scanner/scada/pcomclient msf auxiliary(scanner/scada/pcomclient) > show options Module options (auxiliary/scanner/scada/pcomclient): Name Current Setting Required Description ---- --------------- -------- ----------- ADDRESS 0 yes PCOM memory address (0 - 65535) LENGTH 3 yes Number of values to read (1 - 255) (read only) OPERAND MI yes Operand type (Accepted: Input, Output, SB, MB, MI, SI, ML, SL) RHOST yes The target address RPORT 20256 yes The target port (TCP) UNITID 0 no Unit ID (0 - 127) VALUES no Values to write (0 - 65535 each) (comma separated) (write only) Auxiliary action: Name Description ---- ----------- READ Read values from PLC memory msf auxiliary(scanner/scada/pcomclient) > set RHOST 192.168.1.1 RHOST => 192.168.1.1 msf auxiliary(scanner/scada/pcomclient) > run [*] 192.168.1.1:20256 - Reading 03 values (MI) starting from 0000 address [+] 192.168.1.1:20256 - [00000] : 0 [+] 192.168.1.1:20256 - [00001] : 1 [+] 192.168.1.1:20256 - [00002] : 0 [*] Auxiliary module execution completed msf auxiliary(scanner/scada/pcomclient) >